Body dose distribution assessment in case of accidental exposure using voxel phantom technology
Khamidulin T.M., Soloviev V.Y.
Federal Medical Biophysical Center. AI Burnazyan FMBA Russia
Brief summary
Method of human body dose distribution calculation after nonuniform irradiation, using ICRP Reference Man voxel phantom, has been developed and tested. Two incidents that had happened in the past, with complex geometry between body and radiation source were studied. The results of comparison showed good correlation between calculated and observed data.
Key words
dose assessment, accidental exposure, voxel phantom, monte carlo, modeling
1. Kotenko K.V., Barabanova A.V., Baranov A.E. i soavt. Baza dannih po ostrim lychevim porajeniyam cheloveka. Svidetelstvo o gosydarstvennoi registracii bazi dannih №2010620390 ot 23.07.2010 g. – M.: FMBC im A.I. Byrnazyana FMBA Rossii, 2010.
2. Barabanova A.V., Baranov A.E., Byshmanov A.U., Gyskova A.K. Radiacionnie porajeniya cheloveka. Izbrannie klinicheskie lekcii, metodicheskoe posobie. Pod red. A.U.Byshmanova, V.D.Revi. – M.: firma «Slovo», 2007. – 176 s.
3. Klass E.V., Shahovskii V.V., Kleshenko E.D. i soavt. Rekonstrykciya dozi v slychae avariinogo oblycheniya v Lie (Gryziya). //Atomnaya energiya. – 2006. – T. 100, № 2. – S. 149–153.
5. Aleksahin R.M., Byldakov L. A., Gybanov V.A. i soavt. Krypnie radiacionnie avarii: posledstviya i zashitnie meri. Pod obshei red. L.A. Ilina i V.A. Gybanova. – M.: IzdAT, 2001. – S. 297–306.
7. Radiacionnaya medicina. Rykovodstvo dlya vrachei-issledovatelei i organizatorov zdravoohraneniya. Radiacionnie porajeniya cheloveka. Pod obshei red. Ilina L.A. – M.: IzdAT, 2001. – T. 2. – 432 s.
8. Barabanova A.V. Acute Radiation Syndrome with Cutaneous Syndrome. In: The Medical Basis for Radiation Accident Preparedness. The Clinical Care of Victims. Proceedings of the Fourth International REAC/TS Conference on Medical Basis for Radiation Accident Preparedness. March 2001, Orlando, Florida. The Parthenon Publishing Group. P. 217— 224.